A Brief Introduction to Vibration Analysis of Process Plant Machinery (VI)

Basic Concept VI

Piezoelectric Accelerometers

 
•          Preload screw ensures full contact between crystal & mass
•           When mounted on a vibrating surface seismic mass imposes a force equal to mass x acceleration
•           Charge output of piezo crystal is proportional to applied force
•           Since mass is constant, output charge is proportional to acceleration










Piezoelectric Accelerometers
Converting Charge to Voltage


•          Electronic charge amplifier is required to convert charge signal to voltage signal
–        Impedance of accelerometer is high. Cannot be connected directly to low impedance instruments
–        Charge amplifier has high input impedance and low output impedance so that long cables can be used.
•          Charge amplifier can be external or internal
–        In bigger accelerometers amplifier can be located inside
–        In small, high frequency units amplifier is located outside


Accelerometers Mounting

–        This causes a reduction in the upper frequency range
•          Ideal mounting is by threaded stud on flat surface
–        Maximum stiffness, highest mounted resonance
–        Resonant frequency 32 KHz. Usable range 10 KHz.
•          Magnet mounting simpler but lower response
–        Resonant frequency drops to 7 Khz. Usable range 2 KHz
•          Handheld probe convenient but very low frequency response
–        Due to low stiffness of hand resonant frequency < 2 KHz
–        Frequency response < 1 KHz


 Accelerometers Resonance & Frequency Response

•           Higher the resonance frequency, higher the useful range
•           Maximum useable frequency range is 1/3rd of resonance
•           Resonance frequency, however, depends on mounting
Frequency Response - Screw Mount

•           This film of silicon grease improves contact.
•           Make sure bottom of accelerometer contacts measured surface
 Frequency Response - Magnet Mount

•           Smaller the magnet higher the frequency response
 Use the smallest magnet that holds the accelerometer without slipping. Use a machined surface for the best grip
Frequency Response Hand Held

•           Response may change with hand pressure
•           Repeatability is poor when high frequencies are present
•           Hand holding accelerometers should be avoided except for low frequency work

Filtering Necessary for Accelerometers

•          Any high frequency vibration in the resonant range will be highly amplified. 
–        Amplification can be up to 30 dB or almost 1,000 times
–        Filtered amplitudes will be highly distorted
•          Resonant frequency highly depends on mounting
–        By previous example – 32 KHz for screw mount. Only 2 KHz for handholding
•          Therefore, resonance range should be filtered out
–        For screw mount low pass filter should be set at 10 KHz
–        For hand holding filter should be set at 1 KHz.
–        Analyst must know frequency response of accelerometer used for different mounting conditions.
Filtering can be done in FFT Analyzer by setting maximum frequency correctly.

 Advantages of Accelerometers

•          Measures casing or structural absolute motion
•          Rugged and reliable construction
•          Easy to install on machinery, structures, pipelines
•          Small size, easiest to install in cramped locations
•          Good signal response from 600 to 600,000 CPM
•          Low frequency units can measure down to 6 CPM
•          High freq units can reach 30 KHz (1,800,000 CPM)
•          Operates below mounted resonance frequency
•          Flat phase response throughout operating range
•          Internal electronics can be used to convert acceleration to velocity – Bently Velometer
•          Units available from a cryogenic temperature of minus 200oC to a high temperature of > 600oC

 Disadvantages of Accelerometers
•          Sensitive to mounting and surface conditions
•          Unable to measure shaft vibration or position
•          Not self generating – Need external power source
•          Transducer cable sensitive to noise, motion and electrical interference
•          Low signal response below 600 CPM (10 Hz)
•          Temperature limitation of 120oC for ICP Acceleroms
•          Double integration to displacement suffers from low frequency noise – should be avoided
•          Signal filtration required depending on mounting
•          Difficult calibration check

Machine With Both Shaft and Bearing Housing Vibration Monitoring

 Refferensi Book
  1. Machinery Malfunction Diagnosis and Correction – Robert C Eisenmann – Prentice Hall
  2. Fundamentals of Rotating Machinery Diagnostics – Donald E. Bently – Bently Pressurized Bearing Press